Summary

Addresses post-merge review findings from v0.6 feature PRs (#327, #328, #329) ahead of the v0.6.0 release:

  • Prevent Long-Term Statistics reset spikes & zero-dip artifacts: Return None (unknown) instead of 0 when generator/propane/weather properties are missing on RunTimeSensor, ProtectionTimeSensor, BatteryVoltageSensor, OutdoorTemperatureSensor, CapacitySensor, and WeatherSensor.native_temperature, while preserving explicit 0 readings from the API.
  • Harden ReadinessTracker:
    • Guard async_load() with an asyncio.Lock and mark loaded only after storage reads complete.
    • Keep service_baseline_hours unset (None) until the first valid run_time arrives (and heal legacy beta store records with last_run_time: None and service_baseline_hours: 0.0) to prevent false Day-1 maintenance alerts.
    • Ignore transient drops to 0.0 in both async_update_from_items() and async_reset_service_timer() when a positive last_run_time is already recorded so missed-exercise and maintenance timers aren't corrupted.
  • Honor Options platform toggles: Filter platform setup using entry.options (_enabled_platforms, safely defaulting non-boolean option values to True) and track coordinator.loaded_platforms so unloading/reloading toggles platforms cleanly.
  • Fix propane monitor maintenance_due Repairs alerts: Restrict Mobile Link hasMaintenanceAlert Repairs alerts to generators so propane tank monitors do not surface generator-specific reset prompts.
  • Enforce UI option bounds & defensive parsing: Add shared safe_int_option and safe_float_option helpers across coordinator, readiness, and Repairs evaluation; enforce >= 10 s polling intervals in Options and Reconfigure; cap float options so non-finite floats (NaN/inf) are rejected while Voluptuous schemas remain serializable for the Home Assistant UI.
  • Adaptive polling refinement: Remove Stopped (5) from _ACTIVE_GENERATOR_STATUSES in coordinator.py and README.md so switched-off generators return to idle polling instead of locking at the active interval.
  • Harden & connect bundled blueprints:
    • generac_outage_load_shedding.yaml: Normalize single-string shed_entities, capture pre-outage active loads before shedding so already-off loads aren't turned on, and switch to mode: single with a repeat / wait_for_trigger loop so mid-outage status flaps (Running → Warning → Running) re-shed loads without wiping entities_to_restore.
    • generac_fault_dealer_alert.yaml: Add optional error_code_sensor (default: null) and format notifications with |- + Jinja trimming for clean line breaks.
    • generac_storm_readiness_digest.yaml: Switch optional fuel_level_sensor default to null, add optional remaining_fuel_sensor and estimated_runtime_sensor inputs, and format notifications cleanly across lines with |-.

Testing

  • pytest -v --no-cov: 180/180 passed (including new regression tests for missing-property None behavior, ReadinessTracker edge cases & concurrency, platform toggle reloads, propane Repairs gating, Options/Reconfigure schema bounds & voluptuous_serialize UI compatibility, Stopped polling status, and end-to-end Home Assistant runtime execution of all 3 blueprints).
  • pre-commit run --all-files: All 8 hooks passed (check-added-large-files, check-yaml, end-of-file-fixer, trailing-whitespace, flake8, reorder-python-imports, black, prettier).